Klober Single Pantile Roof Tile Vent For Marley Anglia Plus Or Redland Norfolk Pantile Roof Tiles Red / Brown / Grey

VNTKSPANVT
As low as

£18.95
(£22.74 Incl. VAT)
Availability: In stock
- +

Velux Rewards Q2 2020 Promotion | About Roofing Supplies

Description

Klober Single Pantile Roof Tile Vent For Marley Anglia Plus Or Redland Norfolk Pantile Roof Tiles Red / Brown / Grey

Klober Single Pantile Roof Vent Tile - Simply replaces one tile on the roof, with an in-line design making it unobtrusive on the roof.

Enables ventilation path into roof space.

Adaptor and Flexipipe available separately for soil ventilation or mechanical extraction.

Manufactured from high impact p.v.c.u, making it very tough and able to withstand extreme temperatures.

Complies fully with the relevant Building Regulations and British Standards.

Fits the following concrete interlocking roof tiles:

  • Sandtoft Shire Pantile concrete interlocking roof tiles
  • Redland Norfolk Pantile concrete interlocking roof tiles
  • Marley Anglia concrete interlocking roof tiles
  • Forticrete Centurion concrete interlocking roof tiles

Technical

Technical

  • Material: UV resistant polypropylene
  • Dimensions: 384mm x 229mm
  • Minimum Roof Pitch: 20 degrees

Airflow

  • Performance: Provides 10,000mm/2 vent area
  • Vent Spacing: 5mm Opening @ 2m Centres / 10mm Opening @ 1.0m Centres / 25mm Opening @ 0.4m Centres

Features

  • Low profile design makes it virtually invisible on the roof
  • Fully wind tunnel tested
  • Adaptor available for soil ventilation or mechanical extraction. (Sold separately)
  • Prevents entry of birds and large insects
  • Complies fully with relevant Building Regulations and British Standards
  • Minimum Roof Pitch: 20 degrees
  • Oval spigot on rear of vent tile maximises air flow
  • Complies fully with relevant Building Regulations and British Standards

Fixing

Installation:

  • Lay the roof tiles in the normal manner and determine the location of the vent tile, which must be inline with the tile below
  • Mark a 120 x 180mm wide rectangle on the underlay directly below the tile batten where the vent is to be fixed
  • Carry out a star cut within the rectangle and fold the four tabs back and secure the top tab to the tiling batten
  • Place and fix vent tile in position, ensuring the back of the spigot passes through the underlay, making sure the fixing lug on the underside of the vent tile is located under the left hand interlock of the roof tile
  • Then proceed with the tiling in the normal manner.