Klober Double Roman Roof Tile Vent Red / Brown / Granulated Brown / Granulated Red
In stock
Lead time confirmed upon order
- save
Have a Question?
Our team have wealth of knowledge so why not pick their brains? Call us on 01306 770490.
Delivery Cost
Proceed to the Basket Page and use our Delivery Calculator for your order.
FREE Click & Collect
Simply proceed to the checkout and select one of our stores: Dorking (Surrey), Redhill (Surrey), East Grinstead (Sussex) and Esher (Surrey).
Details
Klober Roof Tile Vent For Redland Double Roman Or Marley Double Roman Roof Tiles
Low profile roof ventilation tile to fit Redland Double Roman interlocking roof tiles, Sandtoft Double Roman interlocking roof tiles, Marley Double Roman interlocking roof tiles & Forticrete Double Roman interlocking roof tiles amongst others.
Simply replaces one tile on the roof.
Manufactured from high impact p.v.c.u, making it very tough and able to withstand extreme temperatures.
Features:
- Low profile design makes it virtually invisible on the roof
- Fully wind tunnel tested
- Adaptor available for soil ventilation or mechanical extraction. (Sold separately)
- Prevents entry of birds and large insects
- Complies fully with relevant Building Regulations and British Standards
- Minimum Roof Pitch: 17.5 degrees
- Oval spigot on rear of vent tile maximises air flow
- Complies fully with relevant Building Regulations and British Standards
Can be connected to a 4" / 100mm Flexipipe with a Klober Tile Vent Adaptor (available separately)
Fixing
Installation:
- Lay the roof tiles in the normal manner and determine the location of the vent tile, which must be inline with the tile below
- Mark a 120 x 180mm wide rectangle on the underlay directly below the tile batten where the vent is to be fixed
- Carry out a star cut within the rectangle and fold the four tabs back and secure the top tab to the tiling batten
- Place and fix vent tile in position, ensuring the back of the spigot passes through the underlay, making sure the fixing lug on the underside of the vent tile is located under the left hand interlock of the roof tile. Then proceed with the tiling in the normal manner.
Technical specification
Airflow
- Performance: Provides 10,000mm2 vent area
- Vent Spacing: 5mm Opening @ 2m Centres / 10mm Opening @ 1.0m Centres / 25mm Opening @ 0.4m Centres
- Minimum Roof Pitch: 17.5 degrees
Technical
- Material: UV resistant polypropylene
- Dimensions: 418mm x 330mm